Document evidence before making the receiving decision.

The checklist measures documentation completeness and exposes unresolved concerns. It does not replace applicable permits, sampling plans, laboratory methods or authorised disposition decisions.

PRACTICAL DECISION WORKSHEET

ULO feedstock quality and load disposition

Document collection-to-refinery evidence against your own approved facility criteria. This tool does not save or transmit data, set universal limits, certify compliance or accept a load automatically.

Load record

Use persistent identifiers. Do not include confidential personal data that is unnecessary for the decision.

1. Load identity and collection record

Connect the physical load to its declared origin, quantity and collection documents.

Load identity matches the collection record

Compare the consignment ID, vehicle, compartment, container and seal details.

Generator or previous holder is identified

Record the source location, responsible organisation and supporting authorisation where applicable.

Transport and transfer evidence is complete

Check the transporter, transfer document, collection date, quantity and handover acknowledgement.

Material source and previous contents are declared

Record the oil family, source process and previous cargo or container contents. Treat unknown as unresolved.

2. Source, legal status and intended route

Apply the current local permit and facility profile. This worksheet does not determine legal classification.

A current facility acceptance profile is identified

Record its version, effective date, jurisdiction and responsible approver in the evidence notes.

Material classification has been reviewed by a responsible person

Confirm that used oil, hazardous waste, solvent, coolant and other legal categories have not been treated as interchangeable.

The site and transporter are authorised for this material

Check applicable permits, registrations and route restrictions before movement or receipt.

The intended treatment or diversion route is lawful and available

Acceptance must be route-specific. A rejected load still requires a lawful destination.

Prohibited sources and mandatory contaminant triggers were reviewed

Record jurisdiction-specific requirements without copying generic thresholds into the facility profile.

Fuel or misfuelled-material risk was declared and reviewed

Treat flash point as a screening property, not as identification or quantification of fuel contamination.

Solvent and halogenated-material risk was declared and reviewed

Unknown source history or solvent use remains unresolved until the applicable classification and analysis are complete.

Coolant, glycol, oily-water and emulsion risk was declared and reviewed

Record known mixing, visible phase separation and the basis for any required confirmatory testing.

Electrical-equipment and PCB-source risk was declared and reviewed

Apply the current jurisdictional requirements and competent analysis where the source could present PCB risk.

Other non-lubricant fluids and process chemicals were declared

Consider brake fluid, acids, alkalis, pesticides, metalworking fluids and other materials outside the accepted-source list.

3. Segregation, arrival and unloading controls

Protect people, the wider inventory and the highest feasible recovery route before commingling.

Vehicle or container condition is safe

Record leaks, structural defects, temperature concerns and any incident response.

Visible condition is documented

Record free water, sludge, sediment, phase separation and unexpected appearance. Odour is an observation, not an acceptance test.

A compatible segregated or guard tank is available

Confirm capacity, tank identity and compatibility with the declared source.

Containment and spill controls are ready

Check secondary containment, connections, unloading controls and the applicable site procedure.

The load remains segregated pending human release

Do not commingle an unidentified, unsampled, unresolved or quarantined load.

4. Sampling, custody and laboratory evidence

An accurate laboratory result cannot repair an unrepresentative or untraceable sample.

An approved sampling plan and method revision are recorded

Confirm that the selected practice covers the material and container type.

The sampling basis addresses stratification

Record mixing or circulation, sample points, free water, sediment and the reason for any composite.

Primary, duplicate and retain samples are identified

Record containers, labels, seal numbers, storage conditions and retention period.

Sample chain of custody is complete

Record the sampler and every transfer to the receiving laboratory or retained-sample store.

Laboratory competence and relevant scope are checked

An accreditation certificate alone does not show that the required method is within scope.

Sampling or analytical deviations are disclosed

Record limitations, invalid samples, substitutions, detection limits and unresolved uncertainty.

5. Analysis and user-entered acceptance criteria

Enter only limits approved for this facility, jurisdiction, material and route. The worksheet does not compare results or determine conformance for you.

Analytical check 1

Analytical check 2

Analytical check 3

Analytical check 4

Analytical check 5

Analytical check 6

Analytical check 7

Analytical check 8

Analytical check 9

Analytical check 10

6. Disposition and sign-off evidence

The worksheet summarises evidence but never certifies or accepts a load automatically.

The selected disposition has a named route and next action

Record the receiving tank, treatment, quarantine condition, return or authorised alternative destination.

An authorised person completed the technical review

Record the reviewer, role, date and decision basis below. Do not use a checklist count as approval.

The decision and subsequent movement will remain traceable

Preserve the original status, retests, overrides, corrections and final physical disposition.

EVIDENCE STATUS

Conservative review summary

38 checklist and analytical entries reviewed.

Documented
0
Unresolved
38
Concern
0
Stop
0
Not applicable
0
Record gaps
9

Evidence remains unresolved. Keep the load segregated and complete the applicable legal, sampling and analytical checks before a human disposition.

Human disposition record

The tool never selects this field. “Accept” means only accept for the specifically named facility route, subject to current legal authority.

Local session only: entries remain in this browser page until it is refreshed, closed or reset. This component does not persist or transmit worksheet data.

How to use the checklist.

  1. Review the load from source and custody records through receiving, sampling, analysis and disposition.
  2. Mark each control as documented, unresolved, concern, stop or not applicable, with evidence and notes.
  3. Take analytical scope and limits from the applicable law, permit, site specification and feedstock risk assessment.
  4. Record the authorised accept, hold, reject or alternative-routing decision separately from checklist completeness.

Check the controlling documents.

These sources inform the workflow. Actual requirements must be taken from the applicable jurisdiction, permit, site specification and risk assessment.

  1. Best Available Techniques Reference Document for Waste TreatmentEuropean Commission Joint Research CentreOfficial reference for waste reception, sampling, checking, analysis and waste-oil treatment.
  2. Waste Treatment BAT Conclusions, Decision 2018/1147European UnionOfficial BAT conclusions covering pre-acceptance, acceptance, tracking and waste-oil monitoring controls.
  3. Guidelines for Environmentally Sound Management of Used Oils in the MediterraneanUnited Nations Environment ProgrammeOfficial guidance covering collection systems, handling, treatment and pollution prevention.
  4. Managing Used Oil: Answers to Frequent Questions for BusinessesUnited States Environmental Protection AgencyCurrent US federal guidance on Part 279 scope and management boundaries.
  5. Used-oil processor analysis plans, 40 CFR 279.55US eCFRCurrent US federal requirements for processor and re-refiner analysis plans.
  6. Used-oil transporter tracking, 40 CFR 279.46US eCFRCurrent US federal shipment and delivery record requirements for used-oil transporters.
  7. Preventing and detecting PCB contamination in used oilUS Environmental Protection AgencyOfficial risk, sampling and record guidance for PCB contamination in used oil.
  8. Waste Oils: Environmentally Sound Management Fact SheetBasel ConventionOfficial international summary of waste-oil risks and environmentally sound management controls.
  9. ASTM D4057, Manual Sampling of Petroleum and Petroleum ProductsASTM InternationalOfficial standard record for manual petroleum sampling; method applicability must be checked.
  10. ASTM D93, Flash Point by Pensky-Martens Closed CupASTM InternationalOfficial standard record for a flash-point method that does not identify a contaminant.
  11. ASTM D6304, Water by Coulometric Karl Fischer TitrationASTM InternationalOfficial standard record for water determination, subject to method scope and matrix interferences.
  12. ASTM D2982, Detection of Glycol-Base AntifreezeASTM InternationalOfficial standard record for qualitative glycol screening and its defined scope.
  13. ASTM D5185, Multielement Analysis by ICP-AESASTM InternationalOfficial standard record for elemental analysis, including particle-size limitations.
  14. ISO/IEC 17025:2017, Testing and calibration laboratoriesInternational Organization for StandardizationOfficial standards record for laboratory competence, impartiality and consistent operation.